Default

As the internal pressure increases (due to things like venting the negative and regulating tanks into the boat, firing torpedoes etc), the indicated depth is then too low, as the gauge is measuring this differential (external water pressure vs pressure in the pressure hull). Bootskunde (the high-level overview document of boat systems issued to every boat) recommended constantly validating the shallow depth gauge reading against that of the Papenberg due to this.