Quote:
Originally Posted by Vorkapitan View Post
When the snorkel tube is elevated, is the sub supposed to automatically run on diesels?

Mine still runs on electric motors, I still run out of oxygen, and Co climbs.

My depth is at 10m.

The mod is installed last.

I'm running this with the "Sub exhaust testing" mission.
Once the snorkel tube is elevated and your depth is in the range for snorkeling the game will automatically switch over to diesel operation. It will also automatically start recharging batteries. Walk back to the diesel room and verify the diesels are running (you'll see the diesel animations are enabled). It is a game bug that O2 levels decrease and CO2 climbs even when snorkel elevated. This requires digging into .exe and .act files to fix which will take time to do.