external resistance "VS-33А" (I - voltage control - II) is implemented en el Mil Mi-8

http://forums.eagle.ru/showpost.php?...&postcount=146
Quote:
News No.11

The external resistance "VS-33А" «I — РЕГУЛИРОВАНИЕ НАПРЯЖЕНИЯ — II» (I - voltage control - II) is now implemented.



After generators are turned on it's needed to activate load and check voltages of the busses. As a load should be turned on: rectifiers, maximum possible quantity of DC consumers, radios and navigation equipment. Voltage can be controlled via rotary switch according to voltmeter VF-0.4-250 indication.



Electrical system also contain voltage control between generators' phases (line voltage), external power and ~115 V lines voltages control. The external resistances "VS-33А" «I — РЕГУЛИРОВАНИЕ НАПРЯЖЕНИЯ — II» (I - voltage control - II) adjust generators' voltages to 204 V. In operation of electrical system phase-to-phase (line voltage) generators' voltages should be within the range of 200 to 208 V.

Fly in a right way.